Masimo Set Radical 7 Signalextraktion Puls CO-Oximeter Patientenmonitor mit.
The Masimo Set Radical 7 Signal Extraction Pulse CO-Oximeter with Docking Station has been extensively studied, with more than 100 independent and objective studies proving its ability to provide highly accurate and reliable SpO2 readings during motion and low perfusion. Its advanced Masimo Rainbow SET technology platform is upgradable through simple field-installed software upgrades, allowing for measurements of total hemoglobin and oxygen content. Additional upgrades offer the ability to continuously and non-invasively measure carboxyhemoglobin, methemoglobin, and PVI, resulting in improved care and reduced medical errors. With enhanced probe-off detection and Rainbow sensors, this pulse CO-Oximeter utilizes cutting-edge technology that has been validated by over 100 studies. The device's color display makes it easy to differentiate critical measurements and respond quickly and accurately.
What's included
-
1x Masimo (optional year)
-
1x Docking Station
-
1x LNC Cable (No SPO2 sensor)
-
1x UK Power supply
Performance
Measurement Range
-
SpO2: 0 - 100%
-
SpMet: 0 - 99.9%
-
SpCO: 0 - 99%
-
SpHb: 0 - 25 g/dL
-
SpOC: 0 - 35ml of O2/dL of blood
-
Pulse Rate: 25 - 240 bpm
-
Perfusion Index: 0.02 - 20%
-
PVI: 0 - 100%
Oxygen Saturation Accuracy (%SpO2)
-
Saturation: 60 - 80%
-
No Motion
- Adults/Infants/Pediatrics: ± 3%
-
Saturation: 70 - 100%
-
No Motion
- Adults/Infants/Pediatrics/Neontates: ± 2%
-
Motion
- Adults/Infants/Pediatrics/Neonates: ± 3%
-
Low Perfusion
- Adults/Infants/Pediatrics/Neonates: ± 2%
Pulse Rate Accuracy
-
Pulse Rate: 25 - 240 bpm
-
No Motion
- Adults/Infants/Pediatrics/Neonates: ± 3 bpm
-
Motion
- Adults/Infants/Pediatrics/Neonates: ± 5 bpm
-
Low Perfusion - Adults/Infants/Pediatrics/Neonates: ± 3 bpm
Carboxyhemoglobin Saturation Accuracy (%SpCO)
-
Adults/Infants/Pediatrics: 1 - 40% ± 3%
Methemoglobin Saturation Accuracy (%SpMet)
-
Adults/Infants/Pediatrics/Neonates: 1 - 15% ± 1%
Total Hemoglobin Accuracy (SpHb g/dL)
-
Adults/Infants/Pediatrics/Neonates: 8 - 17 g/dL + 1 g/dL
Resolution
-
Oxyhemoglobin Saturation (%SpO2): 1%
-
Carboxyhemoglobin Saturation (%SpCO), digital display: 1%
-
Methemoglobin Saturation (%SpMet), digital display: 0.1%
-
Total Hemoglobin (SpHb g/dL): 0.1 g/dL
-
Pulse Rate (bpm): 1 bpm
Electrical
Standalone
-
AC power requirements: 100 - 240 VAC, 47 - 63 Hz
-
Power consumption: 55 VA
-
Fuses: 1 Amp, Fast Acting, Metric, (5x20mm), 250V
Batteries
Handheld
-
Type: NiMH
-
Capacity (battery life): 4 hours
-
Charging time: 3 hours
Standalone (Model RDS-18 Only)
-
Type: NiMH
-
Capacity (battery life): 10 hours
-
Charging time: 8 hours
Environmental
-
Operating temperature: 41°F to 104°F (5°C to 40°C)
-
Storage temperature: -40°F to 158°F (-40°C to + 70°C)
-
Operating humidity: 5% to 95%, noncondensing
-
Operating altitude: 500 mbar to 1060 mbar pressure
-1000 ft to 18,000 ft (-304 m to 5,486 m)
Specifications:
-
Dimensions: 8.9" x 3.5" x 2.1" (22.6 cm x 8.9 cm x 5.3 cm)
-
Standalone: 3.5" x 10.5" x 7.7" (8.9 cm x 26.7 cm x 19.6cm)
Weight
-
Handheld: 1.2 lbs (0.54 kg)
-
Docking Station
- Models RDS-1, 2, and 3: 2.5 lbs (1.14 kg)
- Model RDS-1B: 3.1 lbs (1.41 kg)
-
Standalone
- Models RDS-1, 2, and 3: 3.7 lbs (1.68 kg)
- Model RDS-1B: 4.3 lbs (1.95 kg)